Support

Warranty Information

Browse by:

Products Standard Warranty Document Warranty Extension
1 Raychem BTV self-regulating trace heating cables Standard Policy Online Registration Form | Extended Policy
2 Raychem KTV self-regulating trace heating cables Standard Policy Online Registration Form | Extended Policy
3 Raychem VPL power-limiting trace heating cables Standard Policy Online Registration Form | Extended Policy
4 Raychem XTV Self-Regulating Trace Heating Cables Standard Policy Online Registration Form | Extended Policy
5 1SC-12PT Standard Policy Online Registration Form | Extended Policy
6 1SC-4-6-8PT Standard Policy Online Registration Form | Extended Policy
7 1SC-SSC Standard Policy Online Registration Form | Extended Policy
8 2SC-12PT Standard Policy Online Registration Form | Extended Policy
9 2SC-4-6-8PT Standard Policy Online Registration Form | Extended Policy
10 2SC-LSC Standard Policy Online Registration Form | Extended Policy
11 2SC-LTC Standard Policy Online Registration Form | Extended Policy
12 2SC-SSC Standard Policy Online Registration Form | Extended Policy
13 2SC-STC Standard Policy Online Registration Form | Extended Policy
14 3SC-12PT Standard Policy Online Registration Form | Extended Policy
15 3SC-4-6-8PT Standard Policy Online Registration Form | Extended Policy
16 3SC-LSC Standard Policy Online Registration Form | Extended Policy
17 3SC-LTC Standard Policy Online Registration Form | Extended Policy
18 3SC-SSC Standard Policy Online Registration Form | Extended Policy
19 3SC-STC Standard Policy Online Registration Form | Extended Policy
20 910 Standard Policy |
21 920 Standard Policy |
22 Alloy 825 Standard Policy Online Registration Form | Extended Policy
23 AMC-1A Standard Policy |
24 AMC-1B Standard Policy |
25 AMC-1H Standard Policy |
26 AMC-2B-2 Standard Policy |
27 BTV Standard Policy Online Registration Form | Extended Policy
28 CIT-1 Standard Policy |
29 D1297BRACK Standard Policy Online Registration Form | Extended Policy
30 D1297TERM4 Standard Policy Online Registration Form | Extended Policy
31 E-100 Standard Policy Online Registration Form | Extended Policy
32 E-100-L Standard Policy Online Registration Form | Extended Policy
33 E-100-LBTV2 Standard Policy Online Registration Form | Extended Policy
34 E104 Standard Policy |
35 E-150 Standard Policy Online Registration Form | Extended Policy
36 E304 Standard Policy |
37 E307 Standard Policy |
38 E507S-2LS-2 Standard Policy |
39 E507S-LS Standard Policy |
40 GMK-RAKE Standard Policy Online Registration Form | Extended Policy
41 GMK-RC Standard Policy Online Registration Form | Extended Policy
42 HAK-C-100 Standard Policy Online Registration Form | Extended Policy
43 HAK-JB3-100 Standard Policy Online Registration Form | Extended Policy
44 HBTV Standard Policy Online Registration Form | Extended Policy
45 HQTV Standard Policy | Extended Policy
46 HTPG Standard Policy |
47 HTPI Standard Policy |
48 HXTV Standard Policy Online Registration Form | Extended Policy
49 JBM-100 Standard Policy Online Registration Form | Extended Policy
50 JBM-100-LBTV2 Standard Policy | Extended Policy
51 JBM-SPA Standard Policy Online Registration Form | Extended Policy
52 JBS-100 Standard Policy Online Registration Form | Extended Policy
53 JBS-100-ECP-A Standard Policy |
54 JBS-100-ECW-A Standard Policy |
55 JBS-SPA Standard Policy Online Registration Form | Extended Policy
56 MI-GROUND-KIT Standard Policy Online Registration Form | Extended Policy
57 NGC-30 Standard Policy |
58 PB, 051CUPRON, 107826-000, ETL, LBLSS Standard Policy Online Registration Form | Extended Policy
59 PS-01,03,10,20 Standard Policy Online Registration Form | Extended Policy
60 PTJB Standard Policy Online Registration Form | Extended Policy
61 QTVR Standard Policy Online Registration Form | Extended Policy
62 RAYSTAT-EX-03-A Standard Policy |
63 RMI-JB3 Standard Policy Online Registration Form | Extended Policy
64 RTD-10/20 Standard Policy |
65 RTD-200 Standard Policy |
66 RTD-3CS/10CS Standard Policy |
67 RTD-4AL Standard Policy |
68 RTD-7AL Standard Policy |
69 S-150 Standard Policy Online Registration Form | Extended Policy
70 SB-100-T Standard Policy Online Registration Form | Extended Policy
71 Raychem Series-resistance SC Heat Trace Cables Standard Policy Online Registration Form | Extended Policy
72 SC-JBE-L Standard Policy Online Registration Form | Extended Policy
73 SC-JBE-S Standard Policy Online Registration Form | Extended Policy
74 SC-JB-PIPE-ADAPTER Standard Policy Online Registration Form | Extended Policy
75 SC-JBP-L Standard Policy Online Registration Form | Extended Policy
76 SC-JBP-S Standard Policy Online Registration Form | Extended Policy
77 SC-JBS-L Standard Policy Online Registration Form | Extended Policy
78 SC-JBS-S Standard Policy Online Registration Form | Extended Policy
79 SC-NPLATCIRCUIT-IDTAG Standard Policy Online Registration Form | Extended Policy
80 SLBTV Standard Policy Online Registration Form | Extended Policy
81 System 2000 Standard Policy Online Registration Form | Extended Policy
82 System 2200 Standard Policy Online Registration Form | Extended Policy
83 T-100 Standard Policy Online Registration Form | Extended Policy
84 TT5000 Standard Policy Online Registration Form | Extended Policy
85 TT5001 Standard Policy |
86 TT7000-HUV Standard Policy |
87 TT-FFS (Fast Fuel Sensors) Standard Policy |
88 TT MINI PROBE Standard Policy |
89 TTSIM-1 Standard Policy |
90 TTSIM-1A Standard Policy |
91 TTSIM-2 Standard Policy |
92 TTA-SIM Standard Policy |
93 TTC-1 Standard Policy |
94 TTDM-128 Standard Policy |
95 TT-EMR-SMARTGATEWAY-N5 Standard Policy |
96 TT-EMR-TYPE702-TRANS-I5 Standard Policy |
97 TT-FLASHER-BE Standard Policy |
98 TT-NRM-BASE Standard Policy |
99 PROTONODE-RER-1.5K Standard Policy |
100 VLBTV Standard Policy Online Registration Form | Extended Policy
101 VLKTV Standard Policy Online Registration Form | Extended Policy
102 VPL Standard Policy Online Registration Form | Extended Policy
103 XTV Standard Policy Online Registration Form | Extended Policy
104 TT-AD-1522-1-CRIMPING-TOOL Standard Policy |
105 TT-PR Standard Policy |
106 TT-PTB-1000 Standard Policy |
107 TT-STRIPPER Standard Policy |
108 TT-ULTRATORCH Standard Policy |
109 TT-BCS Standard Policy |
110 TT-CK-TOOL-KIT Standard Policy |
111 TT-CT-SCT-3000 Standard Policy |
112 TT-CPT-MC Standard Policy |
113 TT-KELLEM-GRIP Standard Policy |
114 TT-KELLEM-GRIP-LARGE Standard Policy |
115 TT-MAP-TOOL Standard Policy |
116 TT-MAPPING-CAP-MC Standard Policy |
117 TT-MAPPING-CAP-PC Standard Policy |
118 TT-JC-BLACK Standard Policy |
119 TT-MET-MC Standard Policy |
120 TT-MJC-MC-BLK Standard Policy |
121 TT-MLC-MC-BLK Standard Policy |
122 TT-MBC-MC Standard Policy |
123 TT-JC-CK-MC-M/F Standard Policy |
124 TT-WL-4.5M/15FT-MC Standard Policy |
125 TT-PFT-3/4-MC Standard Policy |
126 TT-TK Standard Policy |
127 TT-ZENER-BARRIER-DIN Standard Policy |
128 TT-5000-CK-MC-M/F-10 Standard Policy |
129 TT-5000-HUV-CK-MC-M/F-10 Standard Policy |
130 TT5000-HS Standard Policy |
131 TT5000-HUV Standard Policy |
132 TT5001-HS Standard Policy |
133 TT5001-HUV Standard Policy |
134 TT-FFS-MOUNTING-BRACKET Standard Policy |
135 TT-FFS-FLOAT ASSY Standard Policy |
136 TT-FFS-PROBE TESTER Standard Policy |
137 TT-3000-CK-MC-M/F Standard Policy |
138 TT-7000-HUV-CK-MC-M/F Standard Policy |
139 TT-TS12 Standard Policy |
140 TTE-XAL Standard Policy |
141 TT-TAG Standard Policy |
142 TT-HDC Standard Policy |
143 NGC-40 Standard Policy |
144 Alloy 825 with PyroFLX Cold Lead Standard Policy | Extended Policy
145 PLI - Power Line Carrier Interface Standard Policy |
146 SES - Smart End Seal Standard Policy |
147 Raychem NGC-20 control and monitoring system Standard Policy Online Registration Form | Extended Policy
148 Raychem NGC-30 control and monitoring panel solution Standard Policy Online Registration Form | Extended Policy
149 Raychem NGC-40 advanced control and monitoring system Standard Policy Online Registration Form | Extended Policy
150 KTV Standard Policy Online Registration Form | Extended Policy
151 XMI-L Standard Policy Online Registration Form | Extended Policy

Where to Buy

Find Your Local Sales Representative & Installers Find a Rep or Installers

Frequently Asked Question (FAQ)

The splice and end seal can be opened and closed without the need to replace parts. If the E-150 end seal is being reused on a new heating cable, use a new sealing boot

(1067)

The installation of both is very simple and well explained in the installation instructions. Remember that the components are cold applied, requiring no torch or heat gun.

(1065)

For Raychem JBS-100, JBM-100, E-100, and E-100-L components, select the appropriate pipe strap from the following list:   Pipes 20 till 47 mm (1/2" to 1 1/4") use pipe strap PSE-047  Pipes 40 till 90 mm (1 1/4" to 3")  use pipe strap PSE-090  Pipes 60 till 288 mm (2" to 10")  use pipe strap PSE-280, except for the JBM-100 where PSE-540 should be used.   For Pipes 60 till 540 mm (2" to 20") , use pipe strap PSE-540 for all kits. These sizes are correct for use with or without the small pipe adapter included in the kit.

(1050)

The QTVR heating cables are approved for use in hazardous area Zone 1 and Zone 2, as well as Zone 21 and Zone 22 by PTB (II 2 G/D EEx e(m) II T4 IP66 T130°C - PTB 98 ATEX 1103 X) and Baseefa (II 2 GD EEx e II T4- BAS98ATEX2337X). They are also VDE approved.

(1161)

The XTV heating cables are approved for use in hazardous areas Zone 1 and Zone 2, as well as Zone 21 and Zone 22, by PTB (II 2 G/D EEx e(m) II T4/T3/250°C(T2 IP66 T130°C, T195°C, T250°C - PTB 98 ATEX 1105 X) and Baseefa (II 2 GD EEx e II T3 and 240°C (T2) - BAS98ATEX2336X). They are also VDE approved.

(1160)

For comfort and energy saving reasons, we recommend to use the Raychem NRG-Temp thermostat. The T2Red self-regulating heating cable requires an inrush current at start up. The NRG-Temp has been designed to withstand this inrush current. If another thermostat is used and the switching capacity of the thermostat is less than 13A, the heating system should be switched on through a contactor.

(1035)

 No. The new components are approved as a system and can not be used in other configurations.

(1138)

Yes. Although the box opening will face a certain direction after installation, that direction can be changed by following the steps shown in the installation instructions.

(1131)

Thermostats like the new RAYSTAT-EX-03 can be directly connected to the box without any additional terminals (JBS) or a reduction of the capacity for the number of heaters (JBM). The power cable coming out of these thermostats can carry phase, neutral and earth.For use with RAYSTAT-EX-02 and similar thermostats that only have one entry, additional WAGO terminals have to be installed in the boxes. You need one phase terminal (WAGO 284-691), one earth terminal (WAGO 284-607), and one end plate (WAGO 284-318) which can be ordered from your local electrical distributor or ordered as a kit from Pentair Thermal Management (HWA-WAGO-TSTAT-KIT). This construction can be used for direct switching up to 25A.

(1127)

The KTV heating cables are approved for use in hazardous areas Zone 1 and Zone 2, as well as Zone 21 and Zone 22 by PTB (II 2 G/D EEx e(m) II T4/T3/226°C(T2) IP66 T130°C, T195°C, T226°C - PTB 98 ATEX 1104 X) and Baseefa (II 2 GD EEx e II 226°C (T2) - BAS98ATEX2335X). They are also VDE approved.

(1162)

The BTV heating cables are approved for use in hazardous area Zone 1 and Zone 2, as well as Zone 21 and Zone 22 by PTB (II 2 G/D EEx e(m) II T6 IP66 T80°C - PTB 98 ATEX 1102 X) and Baseefa (II 2 GD EEx e II T6 - BAS98ATEX2338X). They are also VDE approved.

(1163)

Yes, the TCONTROL-CONT-02 is compatible with most thermocouples and supports volt and mA input as well.

(1278)

Yes, when taking into account the specific environmental requirements which may apply.

(1231)

No, for frost protection, Raychem offers the frost protection  heating cables FS.

(1202)

No.  The hazardous area approval of the thermostats allows for the connection of one cable per terminal entry only.

(1294)

YES.  For this purpose we supply the GL-38-M25-METAL (to be ordered separately).  This cable gland can be used for cables with an outer diameter between 8,5 and 16 mm

(1290)

YES.  The limiting factor is the 16A switching capacity and eventually the cross section of the power feeder cables.

(1289)

Yes, each of the 130 circuits can be individually set up for line sensing, ambient control or PASC.

(1257)

Yes, each of the 130 circuits can be individually set up for line sensing, ambient control or PASC.

(1256)

Inspired Solutions for a Changing World